Quick 4 infiltrator chambers installation software

If youre in the latter group, this page will introduce you to the septic system basics how they work, how to maintain them, and. The quick4 standard chamber supports wheel loads of 16,000 lbs per axle with only 12 of cover and is certified by the international association of plumbing. Larger diameter material or finer substances and runofbank gravel are unacceptable. Design and installation manual for infiltrator chambers in. Instructional video for installing infiltrator quick4 chambers. Infiltrator systems introduces the quick4 plus high. These chambers are an alternative to the traditional gravel drainfields that we also install and offer the following added benefits. Aug 11, 2009 like the original infiltrator quick4 chambers, the easytohandle 4 ftlong quick4 plus standard chambers offer the quickest drainfield installation in the onsite septic wastewater industry. The infiltrator quick 4 leach field chambers are the quick and effective alternative to rock and gravel drain field systems. Infiltrator septic chamber leach field installation versus pipe in gravel stone and pipe septic tank specifications and installation manuals for infiltrator and injection molded heavy duty plastic. For more information about septic system innovation and installation solutions from infiltrator systems, visit our website at or call 800. Wherever you live, you have one of two kinds of wastewater systems. Infiltrator chambers are typically installed in a smaller footprint with equal or better.

Infiltrator manufactures chambers in different sizes and styles to meet all regulatory and site requirements. Call frank gay services to get more information about a. Infiltrator will supply replacement units for units determined by infiltrator to be covered by this limited warranty. Biodiffuser arc 36 leaching chamber is a product in the utility septic tanks category. Infiltrator quick 4 plus standard leach field chambers. The purpose of this product information sheet is to provide specific design and.

Infiltrator is premanufactured, thus guaranteeing installation compliance. Quick4 chamber manuals infiltrator water technologies. Learn proper methods for connecting chambers and endcaps on an infiltrator septic drainfield. Introduction this manual provides general design and installation information for use of arc chambers in the state of vermont. Infiltrator quick 4 plus standard leach field chambers q4.

Offering maximum strength through its two center structural columns and advanced contouring capabilities, the fourfoot long quick4 plus standard chamber is easy to handle and install featuring a new. Quick4 plus installation techniques installation, septic tank. Septic system installation instructions quick4 equalizer. If this type of installation is allowed, call infiltrator water technologies technical services staff at 18007182754 for design and installation instructions.

Call frank gay services to get more information about a free drain field installation estimate. Infiltrator drain field systems are the top of the line septic system material. Infiltrator leaching chamber septic field design tips and tricks the. Ezflow products are certified by iapmo and the icces pmg listing program. Check your local health codes for the specifics in your area. Plus, the chambers 4 ft length and latching mechanism provides optimal installation flexibility. The quick4 plus line of chambers has two end cap options, providing increased flexibility in onsite septic system configurations. The quick4 high capacity chamber offers you these unique benefits. It is illegal to install products that are not lead free in accordance with us federal or other applicable law in. The quick4 plus standard lp chamber is 4 inches shorter than the other standard chamber model, allowing for shallower installation. The purpose of this manual is to provide the minimum design and installation information for the use of quick4. All chambers can be installed in a conventional bed system 15a ncac 18a. Quick 4 eq36 the infiltrator quick 4 leach field chambers are the quick and effective alternative to rock and gravel drain field systems.

The plan below shows the quick 4 domes and states infiltrator quick4 domes to be installed per mfg standards by an infiltrator sys certified installer doesnt say anything if they used gravel sand or just dirt to back fill. Infiltrator quick4 series plastic leach field chambers. Infiltrator quick 4 plus standard leach field chambers 34 x 53 x 12 print. Shop ads hdpe septic chamber in the water pump accessories section of. Quick4 equalizer 36 chamber can be installed in a 24. Learn proper methods for connecting chambers and endcaps on an infiltrator septic drainf. Infiltrator systems quick4 high capacity quick chamber. Fourfoot chamber lengths are easy to handle and install. The advantages of infiltrator chambers over stone and pipe systems. Infiltrator septic systems in lakeland fl in lakeland, fl. Find submittalready datasheets, sds, specs, icces reports. The 48 long vaulted infiltrator chambers replace traditional pvc pipe and crushed stone. Infiltrator water technologies wastewater treatment solutions.

Typically, health departments have approved sizing reductions of 25 to 50 percent when infiltrator chambers are specified. With an interior loadbearing support column, the quick4 plus series provides maximum strength. And, our unique internal manifold promotes lateral flow while reducing area, excavation, material and labor costs. Infiltrator systems introduces quick4 plus low profile lp line of products. In 4 lengths, these plastic leach field chambers are easy to handle and install. The configurations presented in this document are common designs and are provided for illustrative purposes. Chamber lengths are easy to handle and install documents. Septic solutions has all of the components neccessary to build a drain field, including the infiltrator chambers, distribution boxes, pipe inspection ports, and other accessories for low pressure dosing systems. Infiltrator quick4 chambers offer advanced contouring capability. It also shows 3 inspection pipes installed but doesnt have the exact locations. Easy fixes for common drainfield problems onsite installer. An ecofriendly engineered geosynthetic aggregate and pipe system to replace traditional stone and pipe drainfields. Infiltrator is lightweight and economical to transport and store, due to maximised volume storage capacity.

Multiport endcap has six moldedin high and low inlets to allow piping to enter or exit from multiple directions. Provide longterm savings due to longer life and greater operating efficiency offer worry. Watch quick4 plus installation techniques video environmental xprt. Infiltrator chambers are todays superior alternative to oldfashioned stone and pipe because they. Infiltrator systems introduces new quick4 plus standard. Chamber system installation infiltrator chambers can be delivered to the site in a pickup truck and handcarried into position. Sep 10, 20 instructional video for installing infiltrator quick4 chambers. Find 163 listings related to infiltrator septic systems in lakeland fl in lakeland on. The two units are then connected by inserting the pipe through each end cap and into each infiltrator chamber. Compact nesting provides more trench length in equivalent stack height. The chambers can be installed in an 18inchwide or 24inchwide trench, with a minimum soil cover of 4 inches.

The use of infiltrator chambers according to this manual is approved by the indiana. No clogging of the soil from the dusty materials found in gravel trench systems, can support up to 16,000 pounds of accidental loads never drive on your drainfield if you can avoid it, fits in a smaller space than traditional. Many manufacturers may change their products, it is not recommended that you use these spec sheets for cutouts, planning, etc. Infiltrator quick 4 plus standard leach field chambers 34 x 53 x 12 print the quick 4 standard chamber fits in a 36 wide trench and is ideal for curved or straight systems. Like the original infiltrator quick4 chambers, the easytohandle 4ftlong quick4 plus standard chambers offer the quickest drainfield installation in the onsite septic wastewater industry. The new quick4 plus low profile lp family of onsite septic chambers from infiltrator systems provides maximum strength in wastewater treatment applications via its unique, patentpending center structural column design. Contact area is maximized by the fully open bottoms, perforated sidewalls, and the use of cultec no. For most jobs, two people can install a system in less than half the time it. Quick4 equalizer 24 lp chambers the quick4 equalizer 24 lp chamber was designed for shallow. It is recommended that you use the sheets provided with a.

Infiltrators liability specifically excludes the cost of removal andor installation of the units. Colorado delivery only for infiltrator quick4 chamber septic system leach fields. Arc 36 and arc 36 hc system before beginning installation, please note the following engineered features of the arc 36 model chambers and endcaps. Design and installation manual for quick4 plus chambers in indiana. Design and installation manual for infiltrator quick4. Infiltrator systems introduces the new quick4 plus high capacity chamber completing the quick4 plus family of chambers designed for 36inchwide septic system installations. Lightweight chambers are easy to handle and install. Low profile endcap offers a simple overlap design for easy installation in. Ease of installation can be delivered to the site in a pickup truck and handcarried into position for most jobs, two people can install a system in half the time it takes for a comparable stone and pipe leachfield.

Quick 4 eq36 infiltrator quick 4 leach field chambers. Infiltrator quick4 chambers design and installation manual. Available for both septic and potable water storage, imseries tanks are injection molded for strength and. The quick4 equalizer 24 low profile lp chambers can be installed as a gravelless absorption system.

For this particular job, we had to replace the infiltrator system for several possible reasons. At very sharp turns, an eighth or quarter bend may. Infiltrator systems drainfields infiltrator quick 4 chambers. Infiltrator systems are also industry leaders and experts in manufacturing, engineering, science, product development, recycling and government affairs. Bond supply locations get directions to our nearest location. The quick4 plus chamber septic system has a loadbearing support column for maximum. Chambers are 12 high and can be installed in 36 wide trenches. Corrugated plastic pipe delivered in coils is not to be used unless provision is made to prevent the recoiling or movement of the pipe after installation. Designed to provide exceptional strength when used in. Environmental, installation, water treatment, gasket. The chambers are buried, locked endtoend and capped with domeshaped end plates to create a large halftube structure.

Infiltrator systems drainfields infiltrator quick 4 chambers infiltrator quick 4 chambers. Ez flow by infiltrator quick 4 equalizer 36 chamber. Secondly, the homeowner used riddex to clean the septic tank. Quick4 standard chamber infiltrator water technologies. The quick4 plus standard chamber can be installed in a 36. Provide longterm savings due to longer life and greater operating efficiency offer worryfree, longterm service with only simple, routine maintenance. The open bottom and perforated sidewalls of cultec chambers maximize infiltrative.

Chambers are chemicalresistant and uvstable powerful. Infiltrator is quick, simple and easy to install, with minimal damage to landscaping. Infiltrator systems is a graham partners portfolio company. Check with your local health department for the specific codes for your area. Eliminate puddles by collecting and storing water from driveways, patios, gutters, and washing machines. Quick4 plus standard chamber infiltrator water technologies. The quick4 plus line of endcaps is available with these chambers, providing increased flexibility in system configurations. Like the original line of quick4 chambers, quick4 plus systems offer advanced contouring capability. For more detailed design and installation information, please contact infiltrator systems at 18002214436. The chambers unique features, which include a low profile design, make it perfect for shallow placement applications. Infiltrator chambers offer design flexibility and a smaller footprint compared to traditional stone and pipe systems. Infiltrator water technologies is a market leader within the onsite wastewater treatment industry, infiltrator manufactures a variety of revolutionary products and innovative, environmentally friendly alternatives to traditional stone and pipe leachfield and concrete septic wastewater system components.

Infiltrator has a comprehensive quality control program at their companyowned, iso 9001. Septic system installation instructions quick4 equalizer 24. Easy fixes for common drainfield problems improper system siting, hydraulic overload, excess water usage. Submittal data biodiffuser arc 36 leaching chamber. Septic tankblack watercost savingwater systemsplumbingbuildingbuildingsconstructionbathroom fixtures. Septic system installation using infiltrator quick4 chambers. Q4eq36 quick 4 equalizer 36 chamber infiltration sewer panel. Infiltrator in writing at its corporate headquarters in old saybrook, connecticut within fifteen 15 days of the alleged defect. With its contour swivel connection, quick4 chambers offer advanced contouring capability. It is also available in 4 lengths to provide optimal installation flexibility. Quick4 equalizer 24 low profile chamber is designed for shallow placement applications. Fast and easy connection to the biodiffuser chamber makes for quick and easy installation. The equalizer 36 chambers are closed at the ends of a trench with snapon end plates.

Advanced contouring connections swivel 10degrees, right or left. Like the original line of quick4 chambers, it offers advanced contouring capability with its contour swivel connection which permits turns up to 15, right or left. Infiltrator systems introduces quick4 plus low profile lp. Completing the quick4 plus family of maximum strength chambers for flexible onsite system design. It is illegal to install products that are not lead free in accordance with us federal or other applicable law in potable water systems anticipated for human consumption. Directions for installation of the infiltrator system yamhill county. Effluent from a septic tank flows freely into the chambers and is. Instructional video for installing infiltrator quick4 plus chambers. Infiltrator systems introduces the quick4 plus high capacity. You may be connected to a town or city sewer network with a centralized water treatment plant, or you could have your own onsite septic system. How a septic tank works infiltrator water technologies. As regulation, technology and installation techniques continue to develop, everyone in the decentralized wastewater treatment industry is interested in better understanding the reasons why systems fail and the best way to fix them.